Skip to Content

RESPIRATORY PROTECTION

No results found for 'p-point'. Showing results for 'point'.
Full face mask Russia MAG + composite filter 320 A2B2E2
MAG+ 320 A2B2E2 / Sorbent (Rusia)
- MAG consists of a large, durable, transparent glass panel that creates a wide field of view, a soft rubber part surrounding the glass and the skin adjacent to the face consists of 2 layers, durable against the effects of temperature and toxic chemicals.
- Coupling to attach the centrally located filter tank to the inhalation valve
- The structure of the outer and inner hood creates an almost absolute tightness, only allowing breathing air to enter the body after passing through the filter.
- MAG works well in environmental conditions with temperatures ranging from -40 ° to 40 ° C and relative humidity up to 98%
- Conforms to EN 136: 1998 + AC: 2003, Class 2 standards
- Filter 320A2B2E2 filters organic vapors with boiling points above 65 o C, inorganic gases and vapors, acids, and aerosols.
0 ₫ 0.0 VND
Full face mask Russia Silicone MAG-4 + composite filter 320A2B2E2P3
MAG-4 / Sobent - Russia
- MAG-4 includes a large, durable, transparent glass panel that creates a wide field of view, a soft silicone part surrounding the glass and the skin adjacent to the face consists of 2 layers, durable against the effects of temperature and chemicals. poison
- Coupling to attach the centrally located filter tank to the inhalation valve
- The structure of the outer and inner hood creates an almost absolute tightness, only allowing breathing air to enter the body after passing through the filter.
- MAG - 4 works well in environmental conditions with temperatures from -40 ° to 40 ° C and relative humidity up to 98%
- Filter used to protect respiratory organs when working in polluted environments from vapors and organic gases with boiling points above 65OС (such as benzol, benzene, xylene, toluene, kerosene, halogen compounds organic matter, nitrogen, compounds of ben zol and its analogues, aniline, ketones, tetraethyl lead, ...)
- The product meets and exceeds the criteria prescribed by EN 136: 1998 + AC: 2003
0 ₫ 0.0 VND
Full face mask Russia Unix 5000 + filter Unix 502 A2
Unix5000 (MAG-2 )/120+ A1B1E1 / Sorbent (Russia)
- Material: rubber
- Large glass panels help wide field of view, the wearer can observe the whole scene ahead, thus helping them orient themselves well, very useful in emergencies, on the other hand, creating a feeling of not being cramped or confined when using. .
- 2-layer contact (semi-face on the inside and full face on the outside) helps the product have one size but can be used for people with different faces.
- Quick and easy to put on and take off. The carrying strap connects at 5 points allowing for direct adjustment once worn  on the head.
- Selling masks inside helps prevent water vapor from fogging up glasses and reduces CO 2 (carbon dioxide) content in the air inhaled into the lungs;
- Comes with two toxic gas filter boxes #120. Toxic vapor filter cartridge is used to: Filter organic and inorganic vapors, paint spraying, and pesticides
- Meets EN136 Class 2, EN 14387, CE standards
0 ₫ 0.0 VND
Russian composite filter - DOTPro 320 A2B2E2K2P3 RD
DOTPro 320 A2B2E2K2P3 RD / Sorbent - Russia
- Protects respiratory organs from harmful gases, vapors and particles.
- Protection from the following harmful substances: Combination of organic gases and vapors with boiling point > 65C;
Gases, inorganic vapors and acids; Ammonia and its organic derivatives; Very small dust.
- Meets standards: EN 14387
0 ₫ 0.0 VND
Full face mask Russia MAG + filter 320 A2P3RD
MAG / 320 / Sorbent (Russia)
* Products include: full mask and DOT pro 320 A2P3 toxic gas filter. The MAG full-face cover consists of a large, durable, transparent glass panel that creates a wide field of view. The soft rubber border surrounding the glass and the skin on the face consists of 2 layers, durable against the effects of temperature and humidity. toxic chemicals
- Coupling to attach the centrally located filter tank to the inhalation valve
- The structure of the outer and inner hood creates an almost absolute tightness, only allowing breathing air to enter the body after passing through the filter.
- MAG works well in environmental conditions with temperatures ranging from -40 ° to 40 ° C and relative humidity up to 98%
- Conforms to EN 136: 1998 + AC: 2003, Class 2 standards
- Synthetic toxic gas filter DOTpro 320 A2P3 Use with MAG full mask
- Used to protect respiratory organs when working in polluted environments from vapors and organic gases with boiling points above 65OС (such as benzol, benzene, xylene, toluene, kerosene, organic halogen compounds , Nitrogen, compounds of benzol and its analogues, aniline, ketones, tetraethyl lead, ...)
0 ₫ 0.0 VND
Full face mask Russia Unix5100 + Filter 502 A2
Unix 5100 / Sorbent (Russia)*
- Material: Silicon
- Combined with Sorbent filters to create a complete respiratory protection medium, with the best filtration efficiency:
- Unix 502 filter with the ability to filter smoke, gases, organic, inorganic and acid vapors. total oxygen content in the air is at least 17%, filtering toxic substances in the form of vapors and gases with a boiling point above 65 ° C no more than 50 PEL at ambient temperatures from -40 ° C to + 40 ° C.
0 ₫ 0.0 VND
Russian synthetic BMN filter 521 (A1B1E1) (pair of 2)
Synthetic Russian BMN filter 521*
- Use with UNIX semi-mask or MAG-2 full mask to create a complete synthetic toxic vapor filtering respiratory protection.
- Ability: filter organic toxic gas vapor (boiling point >650C); inorganic (such as Cl2, H2S, HCN,...); SO2 and acid.
0 ₫ 0.0 VND
Organic Russian BMN filter 502 (A2) (pair of 2)
DOTeco 120 / 502(A2) / Sorbent (Rusia)*
- Use with UNIX semi-mask or MAG-2 full mask to create a complete synthetic toxic vapor filtering respiratory protection.
- Capability : filtering hazardous substances in the form of vapors and gases with a boiling point above 65 ° C not exceeding 50 PEL at ambient temperatures from -40 ° C to + 40 ° C.
- Complies with EN 14387 standards
0 ₫ 0.0 VND
Phin lọc hữu cơ Sorbent M460-A1B1E1K2+CO
M460-A1B1E1K2+CO / Sorbent (Russia)
- Features: respiratory protection against organic gases and vapors with a boiling point >65°C, inorganic and acidic gases, ammonia and carbon monoxide vapors (protection for 15 minutes)
- Filter designed for use with MAG series respirators
- Filter complies with EN14387:2004
0 ₫ 0.0 VND