Skip to Content

Respiratory Protection

No results found for 'TMMi'. Showing results for 'time'.
Full face mask Russia Unix5100 Silicone + Filter 531 A1B1E1K1
Unix5100 + filter 531 (A1B1E1K1) / Sorbent (Rusia)*
- Material: Silicon
- Filter cartridge 531 with the ability to filter inhaled air from organic, inorganic and acidic gases and vapors, ammonia and its organic derivatives. The filter is used when the volumetric oxygen content in the air is at least 17%, with the content of gases and vapor harmful substances at ambient temperatures from - 40 to + 40 ° C.
- The product meets and exceeds  European standards EN 14387
- Effective time of the filter cartridge :  Test results with sample toxic gas vapors (with specified concentration, flow, temperature, humidity) are much higher than the requirements of the standard EN 14387 - copper Meaning longer usage time. Specifically:
+ protective effect time with  Hydrogen Cyanide is 2 times higher
+ The protective effect time with Chlorine is 2.5 times higher
+ The duration of protective effect with Hydrogen sulfide is 2 times higher
- Respiratory resistance: respiratory resistance is 60% smaller than EN 14387 and EN 143 regulations (equal to 58.8/100Pa). This is an important indicator, especially when used in hard working conditions. Lighter breathing helps the wearer spend less effort and can maintain wearing the mask for a long time.
- Filter box weight: 130g lighter than EN regulations.
- Meets EN136 Class 2, EN 14387, CE standards
0 ₫ 0.0 VND
Russian Ammonia 460K3 filter
DOTpro 460 K3 / Sorbent - Russia
- Use with MAG full mask to create respiratory protection against toxic ammonia gas in the air.
(Can be used with European full face masks)
- The product meets the criteria according to European standards EN 14387:2004 + A1 2008, including:
+ The protective effect time when tested with ammonia concentration of 7 mg/liter is 60 minutes
+ The resistance when an air flow of 30 liters/minute passes through is 140Pa
+ Weight 400g (20% lighter than EN standard regulations)
0 ₫ 0.0 VND
Half mask Russia Unix 1000 + 2 filter Unix 531 A1B1E1K1
Unix 1000 + phin 531 / Sorbent (Russia)*
- Light weight, easy to use.
- Head harness: Easy to use, adjustable for a tight mask by adjusting size in 5 positions.
- Parts of the mask can be disassembled for easy cleaning.
- Designed to not interfere with wearing eye and head protection and noise-canceling earplugs.
- Filters out organic toxic gases; inorganic (such as Cl2, H2S, HCN,...); SO2, acid and ammonia.
- Effective time of the filter cartridge :  Test results with sample toxic gas vapors (with specified concentration, flow, temperature, humidity) are much higher than the requirements of the standard EN 14387 - copper Meaning longer usage time.
- Respiratory resistance: respiratory resistance is 60% smaller than EN 14387 and EN 143 regulations (equal to 58.8/100Pa). This is an important indicator, especially when used in hard working conditions.
- Lighter breathing helps the wearer spend less effort and can maintain wearing the mask for a long time.
-Filter box weight: 130g lighter than EN regulations.
0 ₫ 0.0 VND
PC-EEBD3 3L/15 minute emergency escape air supply
PC-EEBD3 / Penco (Shanghai)
- Breathing air tank capacity: 3L
- Working pressure 200 bar
- Tank material: steel
- Usage time 15 minutes
- Structure: Air tank, pressure reducer, manometer, air pipe, mask set...
- Application: providing breathing air to users in air environments contaminated with dangerous toxic gases and smoke; lack of oxygen
0 ₫ 0.0 VND
Sekur SCBA 9.0liter composite carbon air supply unit
Sekur Type 2 BA 9.0L / Sekur (Italy)
- Breathing time: ~80 minutes
- Gas capacity: 9.0 liters
- Air volume: ~2700 liters
- Pressure: 300 bar
- Storage temperature: -20ºC to 65ºC
- Empty bottle weight: 3.8kg
- Weight of whole set + gas: <12 kg
- According to EU, EN, CE standards, 100% new
0 ₫ 0.0 VND
Sekur SCBA 6.8 liter composite carbon air supply unit
Sekur Type 2 BA / Sekur (Italy)
- Breathing time: ~60 minutes
- Gas capacity: 6.8 liters
- Air volume: 2040 liters
- Pressure: 300 bar
- Working temperature: -20ºC to 65ºC
- Weight of the whole set (empty bottle): 12kg
- Weight of whole set + gas: 18 kg
- Average lifespan of equipment: at least 10 years
- According to EU, EN, CE standards, 100% new
0 ₫ 0.0 VND
SCBA gas supply unit RHZKF6.8/30 (carbon tank/60 minutes)
RHZKF6.8/30 / Penco (Shanghai)
- 6.8 liter air tank made of carbon fiber (so very light).
- Working pressure: 300ba
- Inspiratory impedance: ≤500pa
- Expiratory resistance ≤1000pa
- Warning pressure: 5.5 ± 0.5Mpa
- Warning sound: ≥90db
- Usage temperature: -25 ℃ - 80 ℃
- Usage time 60 minutes.
- Bearing part: Nomex & Kevlar material |
- Lifespan: over 20 years
0 ₫ 0.0 VND
SCBA RHZK6/30 air supply unit (steel tank/60 minutes)
RHZK6/30 / Penco (Shanghai)
- Breathing gas tank: 6L steel tank
- Working pressure: 300bar
- Inspiratory resistance ≤500pa / Expiration resistance ≤1000pa
- Warning pressure 5.5 ± 0.5Mpa
- Warning signal: sound ≥90db
- Temperature: -30 ℃ - 60 ℃
- Usage time 60 minutes
- Published technical specifications: CCS & EC
- Compliant with Fire Safety System requirements according to international regulations and GA124-2004.
0 ₫ 0.0 VND
Half mask Russia Unix 1100 Silicone + 2 Filter Unix 521 A1B1E1
1100 Silicone + 521 / Sorbent - Russia
- Uses: filtering organic toxic gas vapors (organic solvents, acetone, benzene...); inorganic (such as Cl2, H2S, HCN, HCl,...); SO2 and acid.
- Respiratory resistance: only 39.2 Pa, 2.5 times lower than the requirement of EN standard (100/39.2 Pa). This is an important indicator, especially when used in hard working conditions. Lighter breathing helps the wearer spend less effort and can maintain wearing the mask for a long time.
- Effective time of the filter cartridge: Test results with sample toxic gas vapors (with specified concentration, flow, temperature, humidity) are much longer than the requirements of EN 14387 standard - copper Meaning longer usage time:
+ Protection time with Hydrogen Cyanide reaches 50 minutes, 2.5 times longer (50/25 minutes)
+ The protective effect time with Sulfur dioxide reaches 70 minutes, 3.5 times longer (70/20 minutes),
+ The protective effect time with Chlorine reaches 50 minutes, 2.5 times longer (50/20 minutes)
+ The protective effect time with Hydrogen sulfide reaches 80 minutes, 2 times longer (80/40 minutes).

- The manufacturing material is Silicone so it is very soft and comfortable to wear
- Appropriate structure, fits the wearer's face. Does not affect eye vision. Does not affect the need to wear additional protective equipment such as hats, goggles, or face shields.
- The carrying strap has a high elastic feature, the length can be adjusted to fit. Easy and quick to put on and take off. Easy to clean when wiped or cleaned with water or detergent.
- Working temperature from −40 ° C to + 40 ° С.
- Meets EN 140:1998 + AC:1999 standards.
0 ₫ 0.0 VND
Full face mask Sorbent Nga UNIX 6100 silicone - (2-filter type)
UNIX 6100 / Sorbent - Russia
- The UNIX 6100 mask is responsible for isolating the source of polluted air from the respiratory organs and protecting the user's eyes and face. - UNIX 6100 has a viewing frame made of large, durable, transparent glass panels that do not affect eye vision; The border around the glasses and adjacent to the facial skin is made from soft, durable, heat-resistant and chemical-resistant silicone; 2 outer joints to attach the filter box with 2 inhalation valves; The inner half-face covering the nose and mouth has 2 inhalation valves and 1 exhalation valve attached.
- The mask has a well-balanced structure, reducing fatigue for the user even if worn for a long time. The structure of the outer and inner hood creates an almost absolute tightness, only allowing breathing air to enter the body after passing through the filter.
- Environmental conditions from -40°C - 40°C and humidity up to 98%..
- To have a complete full mask set, it is necessary to use an additional filter to create a complete respiratory protection.
- The product meets EN 136: 1998 + AC: 2003 standards
0 ₫ 0.0 VND