Skip to Content

MEASUREMENT - TESTING DEVICES

Phase indicator device KYORITSU 8031F (600VAC/50-60Hz)
8031F / Kyoritsu - Japan
- Operating voltage: 110 - 600V AC
- Fuse: 0.5A/600V (F)
- Continuous duration: >500V: Within 5 Minutes
- Frequency response: 50Hz/60Hz
- Applicable standard: IEC 61010-1 CAT III 600V Pollution Degree 2
- Withstand voltage: 5550V AC For 1 minute
- Dimensions: 106(L) × 75(W) × 40(D)mm
- Weight: 350g
- Cord: 1.5m
0 ₫ 0.0 VND
GIM 60 Digital Inclinometer - BOSCH
GIM 60 / BOSCH
- Length: 60 cm
- Measuring range: 0-360 degrees (4x90 degrees)
- Electronic measurement accuracy 0°/90°: ± 0.05°
- Accurate electronic measurement at 1 – 89°: ± 0.2°
- Measurement accuracy, glass tube foam: ± 0.057° = ± 1 mm/m
- Approximate weight: 0.77 kg
- Measurement units: °, %, mm/m
- Measure tilt accurately in degrees, percent or millimeters/meter
- Directional arrows and audio signals at 0° and 90° make adjustments easy
- The measured value can automatically rotate on the screen when operating in an area above the head
0 ₫ 0.0 VND
Automatic Level BOSCH GOL 32 D
GOL 32 D / BOSCH
- Accuracy: ± 1 mm at 30 m
- Measurement unit: 360 degrees
- Magnification: 32x
- Working range: 120 m
- Protection class: IP 54
- Tripod thread: 5/8"
- Operating temperature: -10 – 50 °C
- Weight, approx.: 1.5 kg
- Working range, value: 120 m
- Compensator lock design for safe transport
0 ₫ 0.0 VND
Automatic Level BOSCH GOL 26 D
GOL 26 D / BOSCH
- Accuracy: ± 1.6 mm at 30 m
- Measurement unit: 360 degrees
- Magnification: 26x
- Working range: 100 m
- Protection class: IP 54
- Tripod thread: 5/8"
- Operating temperature: -10 – 50 °C
- Weight, approx.: 1.5 kg
- Working range, value: 100 m
- Compensator lock design for safe transport
0 ₫ 0.0 VND
SEW 2950CL meter
2950CL / SEW - Taiwan
- Clamp mouth: 35mm Max
- ACA Measuring range: 40/400/1000A (Resolution: 0.01/0.1/1A)
- ACV Measuring range: 4/40/400/750V (Resolution: 1mV/10mV/100mV/1V)
- DCV Measuring range: 4/40/400/1000V (Resolution: 1mV/10mV/100mV/1V)
- Resistance: Measuring range: 400/4k/40k/400k/4M/40MΩ (Resolution: 0.1/1/10/100/1k/10kΩ)
- Overload protection: ACV: 750Vrms ; DCV: 1000V ; Diode & ohm: 250Vrms
- Operating temperature/humidity: 0ºC ~ 40ºC/ 80%
- Battery: 100h continuous operation
- Dimensions: 183(L) × 62(W) × 20(D)mm
- Weight: 123g
- Standard: EN 61010-1 CAT II 600V, CAT III 300V; EN 61010-2-32 ; EN 61326-1
0 ₫ 0.0 VND
Laser Distance Meter GLM 50-27 CG (green laser)
GLM 50-27 CG / BOSCH
- Laser Diode: 515 nm < 1mW
- Measuring range: 0.05 – 50 m
- Extreme accuracy: ± 1.5 mm
- Power supply: 2 1.5V LR6 (AA) batteries
- Maximum measurement time is 4s
- Weight:  approximately 0.2 Kg
- Laser color: Green
- Data transmission: Bluetooth™ 4.2 Low Energy
0 ₫ 0.0 VND
Laser Distance Measurer GLM 150 C
GLM 150 C / BOSCH
- Laser Diode: 650 nm<1mW
- Measuring range: 0.08 – 150 m
- Extreme accuracy: ± 1.5 mm
- Power supply: 3 1.5V LR6 (AA) batteries
- Weight:  approximately 0.23 Kg
- Laser color: Red
- Data transmission: Bluetooth™ Smart
0 ₫ 0.0 VND
Laser Distance Measurer GLM 100-25 C
GLM 100-25 C / BOSCH
- Laser Diode: 650 nm < 1mW
- Measuring range: 0.08 – 100 m
- Extreme accuracy: ± 1.5 mm
- Power supply: 3 1.5V LR6 (AA) batteries
- Maximum measurement time is 4s
- Weight:  approximately 0.23 Kg
- Laser color: Red
- Data transmission: Bluetooth™ 4.2 Low Energy
0 ₫ 0.0 VND
Earth resistance meter 0-2000Om/0-2000 VAC SEW 1120ER
1120ER / SEW - Taiwan
- Measuring range: 0-20Ω / 0-200Ω / 0-2000Ω
- Resolution: 0-20Ω : 0.01Ω / 0-200Ω : 0.1Ω / 0-2000Ω : 1Ω
- Ground voltage measurement: 0-200 Vac/±(1%rdg+2dgt)
- Dimensions: 175(L) × 85(W) × 75(D)mm
- Weight: 600g
- Power: 1.5V (AA) × 8
- Standard: ICE/EN 61010-1 CAT III 200V ; IEC 61557-1 ; IEC 61557-5 ; EN 61326-1
0 ₫ 0.0 VND
Resistance meter 5000V/250GOM SEW 2803IN
2803IN / SEW - Taiwan
- Test voltage (DCV): 0.5kV/1kV/2.5kV/5kV
- Measurement range: 0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ
- Accuracy: 0-50GΩ : ±3% rdg; 50-250GΩ : ±5% rdg
- Dimensions: 170(L) × 120(W) × 95(D)mm
- Weight: 930g
- Power: 1.5V(AA) × 8
- Standard: EN 61010-1 ; EN 61326-1
0 ₫ 0.0 VND
BOSCH D-tect 200 C Multifunction Detector
D-Tect 200 C / BOSCH
- Maximum detection depth:
Detection depth, dry concrete, maximum: 200 mm
Detection depth, young concrete, maximum: 60 mm
Detection depth, other wall types, maximum: 80 mm
Detection depth, magnetic metals, maximum: 200 mm
Detection depth, non-magnetic metals, maximum: 80 mm
Detection depth, live cable, maximum: 80 mm
Detection depth, wooden foundation structure, maximum: 38 mm
- Accuracy: ± 5 mm
- Wall type: Concrete, Young concrete, Dry wall, Regular brick/texture, Horizontal hole brick, Vertical hole brick, Heating board
- Objects that can be detected: magnetic metals (e.g. iron), non-magnetic metals (e.g. copper), electrical cables, non-energetic cables, data transmission cables and low voltage (power cables 3-phase, cavity), water-filled plastic pipes, hollow plastic pipes, wooden base structure
- Power supply: 12V Li-ion battery, 10.8V Li-ion battery or 4 1.5V LR6 (AA) batteries
- Weight: approximately 0.64 kg
- Additional functions: Leak detection, distance measurement
0 ₫ 0.0 VND
SEW PM15 pressure and power gauge
PM-15 / SEW - Taiwan
- AC voltage: 100-240Vrms ; Accuracy ±1%
- AC current: 15Arms; Accuracy ±1%
- Power: 0-3750W; Accuracy ±1%
- Power factor: 0.001-1
- Frequency: 45-65Hz / ±1%
- Cost: 0-9999999 $
- Power consumption: 0-99999 kWh
- Price setting: 0-99,999 kWh,cents/kWh
- Time: 1,8,12,24 Hours / 2,5,7,14,28 Days
- Fuse: 15A/250V
- Dimensions: 135(L) x 80(W) x 35(D) mm
- Weight: 200g
- Standard: EN 61010-1 ; EN 61326-1
0 ₫ 0.0 VND
NOVAX insulating glove testing tool
T-GIK 01 / NOVAX (Malaysia)
- A handheld device that assists users in the process of visually inspecting abrasions, cuts, tears or punctures on insulating gloves
- Glove inflator set includes: Test pump, a carrying bag, and a strap to hold the gloves in place during testing
- Total weight: Approx. 0.9kg
- Recommendation: you should use a pump to check insulating rubber gloves before using them in contact with electricity, to ensure safety and avoid the gloves being exposed, punctured, eroded, etc., causing leaks. Dangerous electricity.
0 ₫ 0.0 VND
Motorized Rotating Mount RM 3 - BOSCH
RM 3 / BOSCH
- Weight: 0.5 kg
- Tool dimensions (length): 135 mm
- Tool dimensions (height): 120 mm
- Multi-functional frame with motor for adjusting laser lines and flexible tool mounting
- Operates with a smartphone via Bluetooth® or RC 2 Professional remote control
- Compatible with the new GCL 2-50 C and GCL 2-50 CG
0 ₫ 0.0 VND
Indirect electrical tester 278HP (240V-275kV)
278HP / SEW - Taiwan
- Indirect type electrical test head, does not contact electrically charged objects
- 8 test voltage ranges: 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV
- Signaling with LED lights and sound
- Frequency: 40-70Hz
- Dimensions: 255mm x 96mm (HxW)
- Uses 3 1.5V batteries
- Compatible with most link bars. Can be used indoors and outdoors
- Maximum detection range can be up to 500kV
- Meets EN 61326-1 standards; EN 55011; EN 61000-4-2; EN 61000-4-3
0 ₫ 0.0 VND
U phase test head 80V~11.4kV AC SEW 279HD
279HD / SEW - Taiwan
- Test voltage range: 80V ~ 11.4kV AC
- Frequency: 50Hz / 60Hz
- Insulation resistance: ≥100MΩ
- Dielectric strength: 20kV for 3 minutes between contact tip and clamp
- Leakage current: 0.12mA or less above dielectric strength
- Starting voltage (direct contact part): Low voltage: 65±15V ; High voltage: 1700±200V.
- Sound emission: 50dB or more (2m apart)
- Operating temperature: 0°C~40°C
- Structure: Waterproof, equivalent to IP65
- Weight (including battery): Approx. 176g
- Power: 1.5V (AAA) x 2
- Safety standard: EN 61326-1
0 ₫ 0.0 VND
U phase test head (6k~81.5kV) 2.45m SEW 290HD
290HD / SEW - Taiwan
- Test voltage range: 6kV~81.5kV
- Operating voltage: 2.7kV (Compared to ground)
- Display: Red light, Sound 50dB at 3m
- Club length: 1370±50mm (retracted) and 2450±50mm (extended)
- Frequency: 50/60Hz
- Withstand voltage: 100kV/300mm for 1 minute
- Insulation resistance: 2000MΩ min at 1kV
- Detection current: 100uA or less than 100uA
- Operating temperature: 0°C~40°C
- Battery source: 2 button-cells LR44 (1.5V)
- Weight: 590g (including battery)
- Standard: IEC / EN 61243-1
0 ₫ 0.0 VND
U phase test head (6k~36.5kV) 1.52m SEW 230HD
230HD / SEW - Taiwan
- Test voltage range: 6kV ~ 36.5kV
- Operating voltage: 2.7kV (Compared to GND)
- Display: Red light, Sound 50dB at 3m
- Club length: 893±50mm (retracted) and 1520±50mm (extended)
- Frequency: 50/60Hz
- Withstand voltage: 100kV/300mm for 1 minute
- Insulation resistance: 2000MΩ min at 1kV
- Detection current: 100uA or less than 100uA
- Operating temperature: 0°C~40°C
- Battery source: 2 button-cells LR44 (1.5V)
- Weight: 485g (including battery)
- Standard: IEC / EN 61243-1
0 ₫ 0.0 VND
Inspection Camera GIC 120 C
GIC 120 C / BOSCH
- Screen size: 3.5"
- Screen resolution: 320 x 240 px
- Camera head diameter: 8.5 mm
- Camera cable length: 120 cm
- Number of LED lighting levels: 3
- Weight: 0.64 kg
0 ₫ 0.0 VND
DALI T8 Thermal Camera
T-8 / DALI - China
- Temperature measurement range from -200C to 6500C
- Temperature measurement accuracy:≤± 2 0C
- Spectral range: 8-14 μm
- Long-distance measurement ability: Capable of capturing heat and clear images from the camera position to heat points on electric poles > 14m high
- Thermal image resolution: 384x288
- Thermal imaging point resolution: 1.37 mrad
- Display results directly on the screen.
- When taking photos, the maximum temperature value and minimum temperature value of the thermal imaging area are displayed on the screen.
- Ability to circle the thermal imaging area to display the maximum temperature value, minimum temperature value, and average temperature value of the thermal imaging area
- Working temperature: -15 0C to +50 0C
- Storage temperature: -400 C to +700 C
- Working environment humidity: 10% to 95%
- Image format in one of the following formats: JPEG/JPG/JPE/BMP/GIF/DIB/PNG/TIF/TI/FF saved directly on camera memory or external memory card, easy to download to computer and read with popular application software such as Microsoft Office, ACD See, Adobe Acrobat...
- Storage memory: save to 8GB memory card
- Safety standards according to: CSA (USA): c22.2 No.61010-1-04, UL:UL STD 61010-1 (2nd Edition) ISA: 82.02.01
- Vibration resistance: 2g, IEC 68-2-6
0 ₫ 0.0 VND