Skip to Content

Clamp Meter

No results found for 'PPWR'. Showing results for 'power'.
LUTRON PC6011SD clamp meter
PC6011SD / LUTRON - Taiwan
- Analyze power quality, 1-phase and 3-phase power.
- True RMS vol and current measurement.
- Measure capacity: KW, MW, GW.
- Measure AC.V: 600V, AC.A: 0 -2000A
- Display measurement chart
- Measure temperature from -100 – 1300
0 ₫ 0.0 VND
SEW 3904CL clamp meter
3904CL / SEW - Taiwan
+ ACA: 400.0/2000A /±(1.5%rdg+4dgt)
+ ACV: 400.0mV,4,000/40.00/400.0/750V /±(1.0%rdg+3dgt)
+ DCA: 400.0/2000A /±(1.5%rdg+4dgt)
+ DCV: 00.0mV/4,000/40.00/400.0/1000V /±(0.75%rdg+2dgt)
+ Ω continuity test: 400.0Ω/4.000/40.00/400.0kΩ/4.000MΩ / ±(1.5%rdg+3dgt) 40.00MΩ ±(2.0%rdg+4dgt)
+ C: 2.000/20.00/200.0nF/20.00/200.0uF/2.000mF ±(3.0%rdg+5dgt)
+ Hz: 4.000/40.00/400.0kHz/4.000/40.00MHz/ ±(1.0%rdg+2dgt)
- Plier ring: 55mm Max.
- Dimensions: 265(L) × 100(W) × 42(D)mm
- Weight: 510g
- Power source: 9V(6F22) × 1
0 ₫ 0.0 VND
KYORITSU 2055 AC/DC Clamp meter (600/1000A)
2055 / Kyoritsu - Japan
AC A : 0~600.0/1000A
DC A : 0~600.0/1000A
AC V : 6/60/600V
DC V: 600m/6/60/600V
Ω : 600/6k/60k/600k/6M/60MΩ
- Continuity check: Buzzer sounds 100Ω
- Frequency: 10/100/1k/10kHz
- Diameter of pliers: Ø40mm
- Effect frequency: 40 ~ 400Hz
- Power source: R03 (1.5V) (AAA) × 2
- Dimensions: 254(L) × 82(W) × 36(D)mm
- Weight: 310g
- Accessories: Measuring probe, Battery, Carrying case, User manual
0 ₫ 0.0 VND
Hioki CM4371-50 Clamp Meter
CM4371-50 / HIOKI - Japan
- DC current measurement range: 20.00 A/600.0 A
- AC current range: 20.00 A/600.0 A
- DC/AC current range: 20.00A/ 600.0A
- DC voltage range: 600.0 mV to 1000 V, 5 scales
- AC voltage range: 6,000 V to 1000 V, 4 scales
- DC/AC voltage range: 6,000 V to 1000 V, 4 scales
- Resistance measurement: 600.0 Ω to 600.0 kΩ, 4 scales
- Capacitance measurement: 1,000 μF to 1000 μF, 4 scales
- Frequency range: 9,999 Hz to 999.9 Hz
- Check continuity:  [ON] 25Ω±10 Ω, [OFF] 245Ω±10 Ω
- Check diode: Open voltage ≤ DC2.0V, short circuit current: 200 μA.
- Temperature measurement:  -40.0 to 400.0 ˚C
- Clamp fork tight diameter: φ33 mm
- DC power measurement: 0.0 kVA to 600 kVA (up to 1200kA when used with Hioki P2000)
0 ₫ 0.0 VND
Kyoritsu 2060BT Clamp meter
2060BT / Kyoritsu - Japan
- AC voltage: 1000 V
- Frequency: 40.0 – 999.9Hz
- Operating power: 40.00/400.0/1000kW
- Reactive power: 40.00/400.0/1000kVA
- Apparent power: 40.00/400.0/1000kVar
- Power factor (cos Ø): -1.000 – 0.000 – +1.000.
- Total harmonic THD-R/THD-F: 0.0% – 100.0%
- Phase order: ACV 80 – 1100V
- Clamp diameter: φ75 mm
0 ₫ 0.0 VND
Kyoritsu 2062BT Clamp meter
2062BT / Kyoritsu - Japan
- AC voltage: 1000 V
- Crest factor: 1.7 or less
- AC current: 40/400/1000 A (3 automatic measurement ranges)
- Frequency: 40.0 – 999.9Hz
- Operating power: 40.00/400.0/1000kW
- Reactive power: 40.00/400.0/1000kVA
- Apparent power: 40.00/400.0/1000kVar
- Power factor (cos Ø):  -1.000 – 0.000 – +1.000.
- Total harmonic THD-R/THD-F: 0.0% – 100.0%
- Phase order: ACV 80 – 1100V (45 – 65Hz)
- Clamp diameter: φ55mm max
0 ₫ 0.0 VND
Kyoritsu 4200 Clamp meter
4200 / Kyoritsu - Japan
- Earth resistance test:
+ Measuring range: 20Ω/200Ω/1200Ω
+ Resolution: 0.01Ω/0.1Ω/1Ω/10Ω
- AC current test:
+ Measuring range: 100mA/1A/10A/30A
+ Display range: 0.1mA/1mA/0.01A/0.1A
- Clamp diameter: Approx. Ø32mm
- Power supply: LR6/R6 (AA)(1.5V) x 4
- Dimensions: 246(L)×120(W)×54(D)mm
- Weight (without battery): 780gc
0 ₫ 0.0 VND
Kyoritsu 4202 Clamp meter
4202 / Kyoritsu - Japan
- Earth resistance test: Measuring range: 0~20Ω/ 0~200Ω/ 0~1500Ω
- AC current test: Measuring range: 100/1000mA/10A/30A
- Clamp diameter: Approx. Ø32mm
- Power supply: LR6/R6 (AA)(1.5V) x 4
- Dimensions: 246(L)×120(W)×54(D)mm
- Weight (without battery): 780g
0 ₫ 0.0 VND
Kyoritsu 2002PA Clamp Meter
2002PA / Kyoritsu
- Clamp diameter: φ 55mm
- Measuring range: 0-2000A AC
- Frequency: 40Hz to 1kHz
- Power supply: R6 (AA) (1.5V) × 2
- Dimensions: 247×105×49mm
- Weight: ~470g
- Standard: IEC 61010-1 CAT III 600V / CAT II 1000V ; IEC 61010-2-031 IEC 61010-2-032
0 ₫ 0.0 VND
Kyoritsu 2200 Clamp Meter
2200 / Kyoritsu
- Clamp diameter: Ø33mm
- AC current: 40.00/400.0/1000A
- AC voltage: 4.000/40.00/400.0/600V
- DC voltage: 400.0mV/4.000/40.00/400.0/600V
- Resistance: 400.0Ω/4.000/40.00/400.0kΩ/4.000/40.00MΩ
- Power source: R03/LR03 (AAA) (1.5V) × 2
- Dimensions: 190(L) × 68(W) × 20(D)mm
- Weight: ~120g
- Accessories: 7107A test probe, Box 9160, R03 (AAA) × 2, Instruction Manual
- Standard: IEC 61010-1 CAT III 600V / CAT II 1000V ; IEC 61010-2-031 IEC 61010-2-032
0 ₫ 0.0 VND
Ampe kìm Kyoritsu KEWSNAP 203
KEWSNAP 203 / Kyoritsu - Japan
- Clamp diameter: 30mm
- AC/DC current measurement range: 40/400A autoranging
- AC/DC voltage measurement range: 400V/600V autoranging
- Resistance measurement range Ω: 400Ω/4000Ω
- Overload voltage: 3700V AC for 1 minute
- Power supply: 2 Ro3 batteries (DC 1.5V)
- Weight: 250 including batteries
- Dimensions: 184 (L) × 44 (W) × 27 (D) mm
- Safety standards: IEC61010-1; IEC61010-2-031; IEC61010-2-032