Ủng chữa cháy theo TT 48
Việt Nam
- Sản xuất theo thông tư 48 Bộ Công An
- Chất liệu: nhựa
- Có lót thép chống đâm xuyên, chống thấm nước
- Là trang bị dùng cho đơn vị dân phòng chữa cháy, không dùng cho lính cứu hoả chuyên nghiệp.
- Màu xám đế đỏ
- Size: 41, 42, 43
0 ₫ 0.0 VND
Penco FB-01 firefighting boots
FB-01 / Penco
- Material: Polyethylene synthetic rubber
- Anti-fingering steel tip
- Anti-pierce inner steel sole. Anti-piercing force ≥1100N
- Withstand voltage ≥5000V. Breaking force  ≥10.78KN
- Color: Black combined with gold
- Weight  3 - 3.6kg / pair (Depending on size)
- Features: Anti-abrasion, anti-cut, anti-puncture, anti-fire, heat-insulating, electrical, anti-oil, anti-slip, anti-acid,  alkali...Very comfortable and pleasant to wear.
0 ₫ 0.0 VND
0 ₫ 0.0 VND
VICADI low voltage insulating boots IEC Size 42
UCD03HA / Vicadi (Vietnam)
- Material: made from natural rubber, red pink color
- Voltage used: 3kV
- Test voltage: 5KV, test time: 1 minute, detection current: <= 9 mA
- Standards apply TCVN 5586 -1991
- There is a factory test card and a typical test card
0 ₫ 0.0 VND
VICADI low voltage insulating boots (38-41)
UCD03HA / Vicadi (Vietnam)
- Material: made from natural rubber, red pink color
- Voltage used: 3kV
- Test voltage: 5KV, test time: 1 minute, detection current: <= 9 mA
- Standards apply TCVN 5586 -1991
- There is a factory test card and a typical test card
0 ₫ 0.0 VND
VICADI 35KV IEC insulating boots (Size 41-42)
U692/IEC35 - Vicadi - Vietnam*
- Material: made from natural rubber, red pink color
- Test voltage: 35KV, test time: 1 minute, detection current: <= 9 mA
- Standards apply TCVN 5586 -1991
- There is a factory test card and a typical test card
- Size 41, 42 IEC
0 ₫ 0.0 VND
VICADI 30KV IEC insulating boots (Size 41-42)
U692/IEC30 / Vicadi (Vietnam)*
- Material: made from natural rubber, red pink color
- Test voltage: 30KV, test time: 1 minute, detection current: <= 9 mA
- Standards apply TCVN 5586 -1991
- There is a factory test card and a typical test card
- Size 41, 42 IEC
0 ₫ 0.0 VND
VICADI 22KV IEC Size 42 insulating boots
U692/CA / Vicadi (Vietnam)
- Material: made from natural rubber, red pink color
- Test voltage: 22KV, test time: 1 minute, detection current: <= 9 mA
- Standards apply TCVN 5586 -1991
- There are factory inspection sheets and typical tests
0 ₫ 0.0 VND
VICADI 22KV insulating boots Size 41
U692/CA / Vicadi (Vietnam)*
- Material: made from natural rubber, red pink color
- Test voltage: 22KV, test time: 1 minute, detection current: <= 9 mA
- Standards apply TCVN 5586 -1991
- There is a factory test card and a typical test card
0 ₫ 0.0 VND
NOVAX DBS4 17kV insulating boots Size 41~42
DBS4 / Novax - Malaysia
- Features: Impact resistance, electrical insulation, chemical resistance, heat resistance, good abrasion resistance, anti-slip
- PE lining to enhance durability.
- Test voltage 20,000V
- Outsole resists electrical surges up to 18kV
- Standards: EN ISO 20345: 2011, EN 50321: 1999, CSA Z195-14 / ASTM F 2413-11, ASTM F1117-03
0 ₫ 0.0 VND
Yotsugi 7kV insulating boots
YS111-09 / Yotsugi - Japan
- Test voltage 20KV
- Working voltage: 7KV (AC)
- Color: brown
0 ₫ 0.0 VND
Yotsugi 26.5kV insulating boots
YS112 / Yotsugi - Japan
- Material: insulating rubber
- Usable voltage 26,500V AC, 39,750V DC
- Test voltage 30,000V AC
- Meets EN, CE, JIS (Japan) and ISO 9001 standards
0 ₫ 0.0 VND
Ty leo trụ 250mm ống logo AB
Ty leo trụ/VN
- Được chế tạo bằng thép vật liệu chịu lực
- Chiều dài: 250mm ± 5%
- Thân ty tròn: F 16mm ± 0,4mm
- Đầu ty có gờ chặn: F22mm dày 4mm
- Mạ lớp kẽm bảo vệ
- Chịu lực uốn: 180kg/5 phút
- Chịu lực uốn làm việc lâu dài: 135kg
- Trên thân có ký hiệu riêng cho từng sản phẩm
0 ₫ 0.0 VND
Cable stripper Juli BXQ-Z-40B
BXQ-Z-40B / Juli
- Weight: 0.9 kg
- Size: 275x95x60mm
- Stripping range: 14-40mm
- Peeling thickness: less than 6mm but for the terminal in the middle 4mm
- Peeling thickness can be adjusted, used for conductors, cable ends and middle peelings
0 ₫ 0.0 VND
Vehicle extractor tool bag
Vehicle extractor bag / Anbaco produces and distributes
- Material: high quality canvas
- Consists of 02 bags that are permanently linked together.
- Square bag, side length 370mm±5%.
- Fabric thickness from ≥1.5mm, guaranteed not to stretch when used
- The bottom and the link between the two bags are sewn in 2 sturdy layers.
- Two pockets with lids covering the entire bag, with padlocks
- Load-bearing bag weight: ≥ 25kg
- Equipping workers in the electricity, water supply, etc. industries to hold electricity and water meters and tools when repairing or using in similar jobs.
- Color: black, blue
0 ₫ 0.0 VND
Tool bag
Tool bags / Anbaco produces and distributes
- Material: High quality, non-stretch canvas
- Used to equip workers, electricians, .... to store tools and equipment in repair, installation, ......
0 ₫ 0.0 VND
Túi cứu thương loại A
Túi A / VN*
- Không chiếm quá nhiều không gian, Đặc biệt thích hợp cho văn phòng hoặc số lượng công nhân khoảng 25 người. 
- Đồ dùng gọn nhẹ đảm bảo chất lượng được sắp ngăn nắp, vệ sinh trong túi. 
- Túi sơ cứu dùng trong các trường hợp bị vấp té đau nhức tay chân nhẹ, trầy xước nhẹ, đứt tay, hoặc làm sạch các vết thương sơ bộ trước khi xử lý‎ các bước tiếp theo.
- Trang bị theo Thông tư số 19/2016/TT-BYT ngày 30 tháng 6 năm 2016 của Bộ trưởng Bộ Y tế ban hành về  Quy Định Về Túi Sơ Cứu Tại Nơi Làm Việc
0 ₫ 0.0 VND
Multi-purpose low voltage grounding 448
448 / Anbaco - Vietnam
- Includes 4 alloy ground clamps
- The clamp head uses a wire clamp with a contact area of ​​50 ~ 300mm², the nose side can be made into a V shape up to 120⁰
- Ground wire made from 16mm² / 25mm² copper wire covered with 1mm PVC
- Set includes 1 piece of wire 1.5m long and 3 pieces 0.4m long connected by an insulated clamp (can be lengthened upon request)
- Used for grounding before performing work on 3-phase low voltage lines, Aptomat output at nuts and cables.
- Industrial design patent No. 21256 issued by the National Intellectual Property Office.
0 ₫ 0.0 VND
Medium voltage mobile grounding 3351
TD - 3351 / Anbaco
- Clamp head made of aluminum alloy
- The hot line clamp has a good spring and is tightened with a threaded ring. The contact surface between the clamp and the wire is large, good and even.
- The clamp head can clamp wires with a cross section of up to 240mm².
- There are 4 clamps for 01 set of ground wires.
- Grounding wire: Multi-strand soft copper wire with clear PVC coating; Uncoated wire cross section is 16mm²/25mm², PVC coating thickness is 1mm.
- There are 4 pieces of wire, each 2m long (or longer as required).
- At each end of the wire attached to the clamp head and the middle point connecting the wire segments, there must be a pressed coss. - At the pressed coss positions, there must be a flexible rubber cover on the outside to prevent the wire from fraying or breaking due to use. long time.
- Used to ground the medium voltage grid with voltage up to 35kV before performing work
0 ₫ 0.0 VND
GAM 220 Digital Protractor - BOSCH
GAM 220 / BOSCH
- Rod length: 40 cm
- Measuring range: 0 – 220°
- Angle measurement accuracy: ± 0.1°
- Water tube foam measurement accuracy: ± 0.05°
- Calculate angle accuracy: ± 0.1°
- Power supply: 4 1.5V LR6 (AA) batteries
- Approximate weight: 1.3 kg
- Automatic deactivation: 30 minutes
- Battery power: 80 hours
0 ₫ 0.0 VND